LoRa fire alarm control panel, LoRa smoke detector, LoRa manual call point, LoRa audible and visual alarm, LoRa fire alarm system, LoRa fire networking system
LoRa fire alarm control panel, LoRa smoke detector, LoRa manual call point, LoRa audible and visual alarm, LoRa fire alarm system, LoRa fire networking system
Customer Service Hotline:

+8613261677119

About Us


LoRa Fire Alarm Control Panel, LoRa Smoke Detector, LoRa Manual Call Point, LoRa Audible and Visual Alarm, LoRa Fire Alarm System, LoRa Fire Networking System

LoRa Wireless Fire Alarm System: Building a Wide-Coverage, Low-Power Smart Fire Network

The LoRa wireless fire alarm system is a smart fire solution based on low-power wide-area network (LPWAN) technology. It consists of terminal devices such as LoRa fire alarm control panels, LoRa smoke detectors, LoRa manual call points, and LoRa audible and visual alarms, forming a complete LoRa fire networking system.

As the core control unit of the system, the LoRa fire alarm control panel adopts an advanced 32-bit microprocessor and can connect hundreds of wireless terminal devices simultaneously. It supports communication in the 433/470MHz frequency band, featuring strong penetration, ultra-low power consumption, and long transmission distance — with a communication range of 1–2 kilometers in open areas and stable signals even in complex urban environments. Equipped with a 7-inch color touchscreen, the panel displays real-time monitoring data, alarms, and fault information, and supports wall-mounted installation.

The LoRa smoke detector uses photoelectric sensing technology to sensitively detect smoke particles in the early stage of a fire, with a built-in high-decibel buzzer (≥85dB). Powered by a 3V lithium battery, it has a quiescent current as low as ≤15μA and a battery life of more than 3 years, supporting low-voltage reporting. The product complies with the national standard GB 20517-2006 and has obtained CCCF mandatory fire certification.

The LoRa manual call point features a striking red design with a built-in high-capacity lithium battery (theoretical design life over 5 years). It supports manual alarm, key reset, low battery alarm, and tamper alarm functions. In case of fire, pressing the button sends an alarm signal to the control panel and cloud platform in real time via the LoRa network. For brands such as Hikvision, the communication distance can reach 1.5–2 kilometers in open areas, with the ability to penetrate 3–5 ordinary walls.

The LoRa audible and visual alarm is powered by a DC24V adapter (non-polarity), requiring no separate wiring and enabling easy installation. It supports LoRaWAN multicast control and can be triggered manually or by fire linkage to meet rapid alarm needs in fire zones. With a sound pressure level of 75–100dB, flash frequency of 1.5–2.0Hz, operating frequency band of 470–510MHz, and line-of-sight communication distance of 700 meters, it is suitable for indoor public places such as hotels, office buildings, and libraries.

The LoRa fire networking system adopts a peer-to-peer network architecture without master-slave hierarchy, allowing each controller to display the operating status of all devices on the network. The system supports networking decentralized fire alarm systems, fire water systems, and more for centralized management via LoRaWAN wireless networks, 4G/5G mobile data networks, and other means. Alarm information can be transmitted to the fire control room or cloud platform within 3 seconds and pushed through multiple channels including mobile APP, SMS, and voice calls.

The entire LoRa wireless fire alarm system requires no wiring construction, features easy installation and low maintenance costs, and is suitable for various scenarios such as nine small venues, old residential communities, cultural relics and ancient buildings, campuses, and hospitals. Having passed multiple national and industrial standard certifications, the system can smoothly pass fire acceptance inspections, building a solid fire safety defense line in a wireless and intelligent manner.

Wanlin LoRa Wireless Fire Alarm System: Building a Wide-Coverage, Low-Power Smart Fire Network

No Wiring Required, Ready for Use upon Installation — Freeing Fire Safety from Cable Constraints

Introduction: Pain Points of Traditional Wired Fire Systems and the Breakthrough of LoRa

In the field of fire safety, although traditional wired alarm systems are stable and reliable, their deployment often causes great headaches:

  • Difficult wiring: Wall slotting, ground excavation, and pipe threading not only damage decoration but also take weeks of construction.

  • High costs: Expenses for wires, pipes, and labor remain high, with fire renovations for medium-sized venues often costing hundreds of thousands of yuan.

  • Heavy renovation burdens: Large-scale wiring renovations are simply impossible for old buildings, cultural relics, and temporary venues.

  • Limited coverage: Traditional wireless solutions often fail to cover signal blind spots such as basements and remote corners.

  • Is there a technology that combines the convenience of wireless installation with long-distance signal penetration and ultra-low power consumption?

    LoRa (Long Range) — long-distance low-power wireless technology — provides the answer.Based on LoRa technology, Wanlin Fire’s LoRa wireless fire alarm system offers a brand-new smart fire solution for nine small venues, three-in-one premises, old buildings, industrial parks, and other places with its unique advantages of wide coverage, low power consumption, easy installation, and high reliability.

    I. LoRa Technology: Born for Fire Safety

    1.1 What is LoRa?

    LoRa is a low-power wide-area network communication technology designed specifically for long-distance, low-rate, low-power IoT applications. Compared with traditional wireless technologies, LoRa has three core advantages:

  • Long transmission distance: Up to 2 kilometers in open areas; able to penetrate multiple walls inside buildings to cover areas unreachable by traditional wireless signals.

  • Strong penetration capability: Using spread spectrum modulation technology, it features strong anti-interference performance and maintains stable communication in complex electromagnetic environments. Communication remains reliable even with one wall between the smoke detector and the gateway.

  • Ultra-low power consumption: Standby current in sleep mode <5μA, average current during data transmission <60mA, allowing battery-powered devices to operate continuously for more than 2–3 years.

  • 1.2 Wanlin LoRa System: Technologically Upgraded

    The Wanlin LoRa868 smart wireless fire alarm system is deeply optimized based on standard LoRa technology:

  • Real-time two-way monitoring: Enables two-way communication between devices and the control panel, truly achieving zero missed alarms and zero false alarms.

  • Hassle-free operation: TFT LCD displays zone addresses; zone locations can be edited via WeChat on mobile phones, with extremely simple operation.

  • Remote management: Connects to the cloud platform via 4G networks to realize remote alarms, remote mute, remote control, and other functions.

  • II. Wanlin LoRa Product Matrix: Full-Scenario Coverage, Flexible Configuration

    The Wanlin LoRa wireless fire alarm system includes a full range of products such as control panels, smoke detectors, manual call points, audible and visual alarms, and gas detectors, allowing users to configure flexibly according to actual needs.

    2.1 Core Brain: LoRa Wireless Fire Alarm Control Panel

    Model: Wanlin LORA868 Series Alarm Control Panel

    Core Functions:

  • Large capacity: Supports 250 wireless alarm zones, compatible with wireless smoke detectors, manual call points, audible and visual alarms, gas detectors, electrical fire detectors, and other devices.

  • Wired-wireless hybrid programming: Supports 6 wired zones, allowing hybrid programming and linkage with wireless zones.

  • Remote transmission: Built-in 4G/GSM communication module, instantly sending alarm information to users’ mobile phones, landlines, and alarm receiving centers.

  • Output control: Two output channels for manual or automatic activation of fans, fire shutters, and other linkage devices.

  • Automatic printing: Automatically prints alarm zones and time for record keeping.

  • Technical Parameters:

  • Wireless frequency: LoRa (transmission distance over 2 kilometers)

  • Power supply: AC 220V 50Hz/60Hz

  • Backup battery: DC7.4V/2100mAh, operating time ≥8 hours

  • Operating temperature: -20~+60℃

  • Dimensions: 22.5cm (L) × 23.5cm (W) × 6.5cm (T)

  • 2.2 Smart Sensing: LoRa Wireless Smoke Detector

    Model: WANLIN-304 Standalone Smoke Fire Detector LoRa

    Core Highlights:

  • No wiring required: Battery-powered (3V AA battery), service life over 2 years.

  • Simple installation: Wall or ceiling mounted, completed in 30 seconds, ready for use upon installation.

  • Long-distance communication: Up to 2 kilometers between the detector and gateway in typical environments.

  • Strong anti-interference: Unique anti-insect, anti-strong light, and anti-strong magnetic technologies, ensuring no missed or false alarms.

  • Technical Parameters:

  • Standard: GB 20517-2006 (CCCF certified)

  • Sound level: >80dB (frontal)

  • Status light: Self-test flash every 50 seconds; continuous flashing indicates alarm

  • Operating temperature: -10℃~+50℃

  • Operating humidity: ≤95% (40℃, non-condensing)

  • 2.3 Active Early Warning: LoRa Wireless Manual Call Point

    Model: WANLIN-211 LoRa Manual Fire Call Point

    Core Highlights:

  • Battery-powered: Lithium-manganese battery (123A), service life over 3 years, no external power needed.

  • Reusable: Easily reset with tools after alarm activation for repeated use.

  • Easy installation: No wiring, wall-mounted only.

  • Clear indication: Red light stays on when pressed to signal an alarm.

  • Technical Parameters:

  • Standard: GB 19880-2005

  • Communication distance: 2km radius in typical environments (one wall between call point and gateway)

  • Operating temperature: -10℃~+50℃

  • Dimensions: 85mm (L) × 85mm (W) × 4mm (T)

  • 2.4 Powerful Warning: LoRa Wireless Audible and Visual Alarm

    Core Highlights:

  • Dual warning: Over 85dB loud alarm + red LED flashing to ensure on-site personnel are alerted immediately.

  • Custom voice: Supports customized voice prompts such as “Fire emergency, please evacuate quickly”.

  • Remote mute: Mute remotely via control panel or APP without on-site operation.

  • Independent power supply: DC12V powered, usable with an adapter.

  • Technical Parameters:

  • Standard: GB 26851-2011

  • Sound level: 80–100dB (frontal)

  • Flash frequency: 1.0–1.3Hz

  • Communication distance: 2km radius in typical environments

  • 2.5 Preventing Risks: LoRa Wireless Gas Leak Detector

    Core Highlights:

  • High sensitivity: Uses highly stable semiconductor gas sensors for stable and sensitive detection.

  • Automatic reset: Automatically resets when combustible gas concentration falls below the alarm threshold; also resettable via APP.

  • Audible and visual indication: Red for alarm, yellow for fault, green for power supply.

  • National certification: Certified by the National Fire Certification Center.

  • Technical Parameters:

  • Standard: GB15322.2-2003 (CCCF certified)

  • Detected gases: Natural gas, liquefied petroleum gas

  • Alarm concentration: 7%LEL

  • Power supply: AC220V

  • III. Revolution in Convenience: How Wanlin LoRa System Simplifies Installation

    3.1 From “Wiring Construction” to “Ready for Use upon Installation”

  • Traditional fire system installation: Site survey → Drawing design → Slotting and piping → Wiring → Equipment installation → Commissioning → Duration: weeks to months

  • Wanlin LoRa system installation: Site survey → Install control panel (power connection) → Install sub-devices (wall/ceiling mounting) → Mobile QR code binding → Completed in 30 minutes

  • Compared with traditional wired systems, wireless deployment reduces installation time by 70% and renovation costs by 60%, making it especially suitable for old building renovations.

    3.2 Four Aspects of Convenience

    ① Easy installation: No wiring, no decoration damage

  • Sub-devices such as smoke detectors and manual call points are all battery-powered with no external power required.

  • Wall or ceiling mounted with screws or 3M adhesive without damaging decoration.

  • The control panel only requires power connection and SIM card insertion for plug-and-play use.

  • ② Easy configuration: Address editing via WeChat

  • Zone addresses can be edited via mobile WeChat (e.g., “Reception of XX Shop, XX Street”).

  • Supports one-click import of alarm points via Excel and automatic floor creation.

  • ③ Easy commissioning: Two-way communication, automatic code pairing

  • Automatic code pairing between devices and control panel without professional operation.

  • Real-time signal strength display on the control panel for easy position adjustment.

  • User-friendly interface operable by ordinary staff after simple training.

  • ④ Easy maintenance: Remote self-inspection, automatic reminders

  • Regular device self-inspection (configurable every 8/12 hours) with real-time status upload.

  • Automatic push reminders for low battery, faults, and offline status without manual inspection.

  • Remote mute and reset via APP to reduce on-site trips.

  • IV. Flexible Networking: Wired + Wireless Hybrid Programming for Complex Needs

    The Wanlin LoRa system supports not only pure wireless networking but also advanced wired-wireless hybrid programming.

    4.1 Wired/Wireless Hybrid Networking

    Taking the Wanlin JB-QB-WL800 Fire Linkage Controller as an example:

  • 2 wired loops: 2-wire bus connection, supporting 192 wired points.

  • 2 wireless loops: LoRa communication at 470MHz, supporting 200 wireless points.

  • Hybrid linkage: Wired and wireless loops can interlock; wireless alarms can trigger linkage devices via wired modules.

  • Application Value:

  • Wired connection for core areas to ensure maximum stability.

  • Wireless connection for hard-to-wire areas for convenience.

  • Eliminates tedious wiring while ensuring reliable wireless activation.

  • 4.2 Multi-Level Networking Architecture

  • Single-point networking: One control panel operates independently to manage all wireless devices on-site.

  • Regional networking: Multiple control panels connect to the Wanlin Cloud Platform via 4G/wired networks for centralized multi-project supervision.

  • City-level networking: Networks with sub-district offices, fire brigades, and emergency command centers to form a urban security brain.

  • 4.3 Remote Monitoring Platform

    The Wanlin Smart Fire Cloud Platform connects seamlessly with the LoRa system to provide:

  • Remote alarm push via APP, SMS, and calls.

  • Remote control: mute, reset, start/stop linkage devices.

  • Online CRT: Automatic building floor plan display with alarm locations.

  • Data analysis: Statistics of alarm frequency and equipment status for optimized fire management.

  • V. Application Scenarios

    Scenario 1: Nine Small Venues / Street Shops

    Deploy LoRa wireless smoke detectors + manual call points + audible and visual alarms, with the control panel at the cashier desk. Shop owners receive real-time alarms via APP — no wiring, no decoration damage, ready for use.

    Scenario 2: Old Communities / Courtyards

    Install LoRa wireless smoke detectors and manual call points in corridors and public areas, connecting to community mini fire stations via LoRa control panels. Battery-powered, wireless, and wide-coverage.

    Scenario 3: Cultural Relics & Ancient Buildings

    Full wireless deployment with battery-powered devices and wall-mounted installation to preserve architectural features. Strong LoRa signal penetration covers complex structures.

    Scenario 4: Industrial Parks / Warehouses

    Long LoRa transmission (over 2km) covers large workshops; battery-powered devices fit remote corners without power; 250 zones support large-scale deployment.

    Scenario 5: Temporary Venues / Prefabricated Buildings

    Devices are ready for use upon installation and removable for recycling after events. Battery-powered with no temporary wiring needed.

    Scenario 6: School Dormitories / Nursing Homes

    Wireless smoke detectors + audible and visual alarms installed in corridors and activity rooms. On-site alarms guide evacuation while remote alerts notify duty rooms and managers.

    VI. Why Choose Wanlin LoRa? — Hard Strength Behind Convenience

    6.1 Authoritative Certification, Quality Assurance

    All Wanlin LoRa products are tested by the National Fire Equipment Quality Supervision and Inspection Center and hold CCCF certification.

    6.2 Leading Technology, Reliable Performance

  • Transmission distance: Over 2km radius in typical environments.

  • Anti-interference: 10x improved performance via spread spectrum modulation.

  • Communication reliability: 99.9% in complex electromagnetic environments.

  • Power control: Sleep current <5μA, average transmission current <60mA.

  • 6.3 Remote Management, Intelligent Efficiency

  • Centralized multi-project supervision via cloud platform.

  • Real-time APP alarms and remote operations.

  • Video linkage verification with automatic camera pop-up.

  • Data analysis for optimized fire safety management.

  • VII. Conclusion

    The Wanlin LoRa wireless fire alarm system redefines fire alarm installation and maintenance through technological innovation. It turns fire deployment from major construction into simple setup, enables modern fire protection for old buildings, and eliminates fire blind spots.

    Choosing Wanlin LoRa means choosing:✅ No wiring — no decoration damage, 30-minute deployment✅ Long battery life — 2–3 years maintenance-free✅ Long-distance transmission — 2km coverage, strong penetration✅ Authoritative certification — CCCF approved✅ Smart management — real-time APP control and remote operation✅ Flexible networking — wired-wireless hybrid for complex needs

    LoRa wireless fire protection makes safety everywhere.

    Wanlin IoT Technology Co., Ltd.— Connecting every fire device wirelessly, securing every place safely.

    (Note: Specific product parameters are subject to the latest official release. Wanlin LoRa series products have passed testing by the National Fire Equipment Quality Supervision and Inspection Center and comply with relevant national standards.)

    Service Hotline: +86 132 6167 7119


    News and Trends