LoRa Fire Alarm Control Panel, LoRa Fire Alarm Receiver, LoRaWAN Fire Control Panel, LoRa Intelligent Fire Alarm Host, LoRa Wireless Fire Alarm Panel
LoRa Fire Alarm Control Panel, LoRa Fire Alarm Receiver, LoRaWAN Fire Control Panel, LoRa Intelligent Fire Alarm Host, LoRa Wireless Fire Alarm Panel
Customer Service Hotline:

+8613261677119

About Us

Global Partnership Invitation – LoRa Fire Alarm Control Panel Manufacturer China

LoRa Fire Alarm Control Panel | LoRa Fire Alarm Receiver | LoRaWAN Fire Control Panel | LoRa Intelligent Fire Alarm Host | LoRa Wireless Fire Alarm Panel

OEM/ODM | Custom Development | Factory Visit Welcome | Round-Trip Airfare Reimbursement | Free Accommodation and Meals

Are you a global trade partner, cross-border e-commerce seller, sourcing agent, or local distributor looking for a direct Chinese manufacturer of LoRa fire alarm control panels?

Do you want to source LoRaWAN fire control panels and LoRa wireless fire alarm panels without dealing with trading company markups?

Wanlin Fire Technology – a verified manufacturer of home fire alarm and detection devices – is now expanding our international partner network. We specialize in long-range, low-power LoRa fire alarm control and receiving technology and are ready to become your long-term supplier.

We are not a middleman. We are the source factory. We offer complete export solutions for LoRa fire alarm control panels, LoRa fire alarm receivers, LoRaWAN fire control panels, LoRa intelligent fire alarm hosts, and LoRa wireless fire alarm panels. Our philosophy is simple: win-win cooperation, quality assurance, and exceptional service for every global partner.

Our Core Product Line – LoRa Fire Alarm Control Panel Deepened

LoRa fire alarm control panels (FACPs) serve as the central brain of a LoRa-based wireless fire alarm system, receiving signals from hundreds of wireless detectors, displaying alarm status, activating notification appliances, and communicating with central monitoring stations. Unlike traditional panels requiring wired connections to every device, LoRa panels receive signals wirelessly over kilometers, dramatically reducing installation cost and time. All products are designed to meet CE, RoHS, EN54, UL864, FCC, and UKCA certifications.

1. LoRa Fire Alarm Control Panel

  • Central control panel for LoRa-based wireless fire alarm systems, receiving signals from up to 500 LoRa detectors

  • Built-in LoRa gateway with selectable frequency bands (EU868, US915, AU915, AS923) for global deployment

  • Large 4.3 inch or 7 inch color touchscreen display showing device status, alarm locations, and event history

  • Supports up to 500 wireless devices including smoke detectors, heat detectors, CO detectors, manual call points, and input modules

  • 2 to 8 notification appliance circuits (NACs) for horns, strobes, and bells (optional)

  • 2 to 8 programmable relay outputs for HVAC shutdown, elevator recall, door release, and fire suppression

  • 4 to 16 input zones for conventional wired detectors (hybrid mode)

  • Event logging: 1000 to 5000 events with time and date stamps

  • Battery backup: built-in battery charger supports 12V 7Ah to 26Ah batteries for 24-72 hour standby

  • Ethernet, Wi-Fi, and 4G LTE cellular communication options for central station reporting

  • Contact ID and SIA DC-09 protocols for professional monitoring station integration

  • RS485 port for expanding to additional annunciators or remote displays

  • USB port for configuration backup, firmware updates, and event log export

  • 24V DC output (2-5 amps) to power external devices

  • Wall-mount cabinet: 12 x 12 x 4 inches (standard) or 16 x 16 x 6 inches (expanded)

  • Operating temperature: -10°C to +55°C

  • Ideal for commercial buildings, industrial facilities, schools, hotels, and healthcare facilities

2. LoRa Fire Alarm Receiver

  • Dedicated LoRa fire alarm receiver for monitoring LoRa wireless detectors without full panel features

  • Compact design for integration into existing fire alarm systems as wireless expansion module

  • Receives signals from up to 128 LoRa detectors per receiver

  • Selectable frequency bands: EU868, US915, AU915, AS923, IN865, KR920

  • 8 to 16 dry contact relay outputs (Form C) for connection to conventional fire alarm panel zones

  • Each relay can be programmed to activate for specific device or group of devices (zone mapping)

  • RS485 Modbus RTU interface for integration with building management systems (BMS)

  • Ethernet and Wi-Fi for remote monitoring and configuration

  • LED indicators: power, LoRa RX/TX, alarm, fault, and zone status

  • 12V or 24V DC powered (wide input range 9-30V DC) with battery backup connection

  • DIN rail mountable or wall-mount enclosure options

  • Simple web interface for device pairing, zone assignment, and system configuration

  • AES-128 encrypted communication with all paired devices

  • Ideal for retrofitting wireless detectors to existing wired fire alarm systems

3. LoRaWAN Fire Control Panel

  • LoRaWAN standard compliant fire alarm control panel for open ecosystem integration

  • Compatible with public and private LoRaWAN network infrastructure (TTN, ChirpStack, Loriot, Actility)

  • Standard LoRaWAN Class C operation for low-latency downlink to detectors and notification appliances

  • Supports up to 1000 LoRaWAN end devices (smoke, heat, CO, manual call points)

  • Integrates with existing LoRaWAN infrastructure – can use existing gateways

  • 10.1 inch full-color touchscreen display with floor plan mapping and device location overlay

  • Built-in LoRaWAN network server (NS) or connect to external NS via API

  • Professional monitoring station interface: Contact ID, SIA DC-09, or REST API

  • Multi-tenant support: manage multiple buildings or client sites from single panel

  • Remote firmware updates for all connected end devices via LoRaWAN downlink

  • Geolocation support: visualize device locations on uploaded floor plans or GPS maps

  • BACnet and Modbus integration for building automation systems

  • UL864 and EN54-2, EN54-4 certified for commercial fire alarm applications

  • Ideal for smart buildings, university campuses, hospitals, and large commercial facilities

4. LoRa Intelligent Fire Alarm Host

  • Advanced intelligent fire alarm host with edge computing and artificial intelligence capabilities

  • 12.1 inch industrial-grade capacitive touchscreen display with high brightness (1000 nits)

  • Built-in LoRa gateway with diversity antenna for maximum reception reliability (dual antennas)

  • Supports up to 2000 wireless detectors per host (expandable to 5000 with additional gateways)

  • Intelligent alarm verification: requires confirmation from multiple detectors before full alarm (reduces false alarms)

  • Self-learning algorithms: system learns normal background sensor readings and adapts thresholds

  • Voice evacuation capability: built-in digital voice messages for occupant instructions (40+ languages)

  • Bi-directional communication: panel can poll detectors, request status, and silence from central location

  • Predictive maintenance alerts: identifies detectors showing degradation before they fail

  • Remote diagnostic testing: conduct full system test from panel without manual testing

  • Dual LoRa radios for redundant communication paths and frequency agility

  • Dual power supplies with automatic failover (AC mains + battery + optional generator input)

  • UL864 and EN54-2, EN54-4, EN54-16 certified

  • Ideal for critical infrastructure, data centers, airports, government buildings, and industrial facilities

5. LoRa Wireless Fire Alarm Panel

  • Compact, cost-effective LoRa wireless fire alarm panel for smaller applications

  • Supports up to 32 to 128 wireless detectors depending on model

  • 3.5 inch color LCD display with intuitive menu navigation

  • Built-in LoRa gateway with fixed frequency band (selectable at order)

  • 2 to 4 notification appliance circuits (NACs) for local horns and strobes

  • 2 to 4 programmable relays for auxiliary control

  • 24-hour backup battery built-in (no external battery box required)

  • Plug-and-play configuration: devices auto-register with QR code scanning

  • Simple one-button test function for entire system

  • Wall-mount enclosure: 10 x 10 x 3 inches (compact)

  • Ideal for small businesses, churches, daycare centers, medical offices, retail stores, and residential common areas

All products undergo 100 percent pre-shipment quality control including LoRa radio testing (TX power, RX sensitivity, frequency accuracy), device pairing and communication testing, alarm response time validation, relay output testing, battery charger verification, environmental chamber testing, and accelerated life testing. Multi-language user manuals and software interfaces available.

Technical Advantages of LoRa Fire Alarm Control Panel Technology

Traditional fire alarm control panels require expensive shielded wiring from every detector back to the panel. For large buildings and campuses, this can cost hundreds of thousands of dollars. LoRa fire alarm control panels eliminate this cabling entirely, receiving signals wirelessly from detectors over kilometers, while still providing all the features of a professional fire alarm system.

How LoRa Fire Alarm Control Panels Work

  • LoRa gateways built into the panel receive wireless signals from up to 500-2000 detectors

  • Detectors automatically register with panel using secure AES-128 encryption

  • Panel continuously monitors each detector's status (normal, alarm, trouble, low battery, tamper, offline)

  • When detector detects fire, it sends alarm signal to panel in under 2 seconds

  • Panel activates local horns/strobes, shows alarm location on display, and sends notification to monitoring station

  • All events logged with timestamp for compliance and investigation

Key Capabilities of Wanlin LoRa Fire Alarm Control Panels

  • Wireless device management: pair, configure, and monitor all detectors from central panel

  • Device supervision: panel polls each detector periodically to verify communication; trouble alert if detector offline for programmed time (typically 60-120 minutes)

  • Low battery monitoring: panel displays battery level for each device; alert when battery reaches replacement threshold

  • Tamper monitoring: panel receives and displays tamper events (cover opened, device removed from base)

  • Alarm verification: panel can require two detectors in same zone to alarm before full alarm activation (reduces false alarms)

  • Event history: up to 5000 events stored with time, date, device ID, and event type

  • Remote communication: panel sends alarm, trouble, and supervisory signals to central monitoring station via Ethernet, Wi-Fi, or 4G cellular

  • Notification appliance control: panel activates horns, strobes, and bells when any detector alarms

  • Auxiliary control: panel can shut down HVAC, recall elevators, release magnetic door holders, and activate fire suppression systems

LoRa Versus Traditional Wired Fire Alarm Panels

  • Installation cost: LoRa panels eliminate 80-90 percent of installation cost (no wiring between detectors and panel)

  • Installation time: Days instead of weeks for large facilities

  • Retrofitting: Add fire alarm protection to buildings that cannot be wired (historic buildings, finished occupied spaces)

  • Expansion: Add new detectors without pulling new cables

  • Relocation: Move detectors easily as facility layout changes

  • Remote monitoring: Check panel status and device health from anywhere via built-in web server

Wanlin's LoRa fire alarm control panels use certified Semtech SX1302 or SX1303 gateway chips for high-capacity concurrent reception. Each panel undergoes individual radio calibration and device pairing testing before shipment.

Custom Development and OEM/ODM – Your Brand, Your Specifications

We understand that every market has unique requirements. Wanlin offers full customization for all our LoRa fire alarm control panel products.

Housing and Enclosure

  • Custom colors according to any RAL or Pantone code

  • Logo engraving, embossing, or silk-screening on front door and enclosure

  • Enclosure size: wall-mount standard, flush-mount, or 19-inch rack-mount

  • Door lock type: key lock, combination lock, or card reader

  • Glass window option (to view display without opening door)

  • Weather-resistant enclosure for outdoor installation (IP54, IP65)

  • Explosion-proof enclosure for hazardous locations (Class I Division 2)

Display and User Interface

  • Display size: 3.5 inch, 4.3 inch, 7 inch, 10.1 inch, or 12.1 inch

  • Display type: color TFT LCD with touchscreen or non-touch with buttons

  • Display brightness: standard (400 nits) or high-brightness (1000 nits) for outdoor/bright locations

  • Languages: English, Spanish, French, German, Italian, Polish, Russian, Arabic, Chinese (selectable)

  • Custom splash screen with your logo on startup

  • Custom menu structure and terminology for your market

LoRa Radio Configuration

  • Frequency band: EU868, US915, AU915, AS923, IN865, KR920, RU864

  • Number of LoRa radios: 1 (standard), 2 (redundant/diversity), or 4 (high-capacity)

  • Gateway chip: SX1302 (standard) or SX1303 (high-performance, 8 channels)

  • Antenna: internal (panel-mounted), external (wall-mounted with cable), or remote (building rooftop)

  • Encryption: AES-128 or AES-256

Device Capacity and Zones

  • Wireless device capacity: 128, 250, 500, 1000, 2000, or 5000 devices

  • Number of NAC (notification appliance) outputs: 2, 4, 6, 8, 12, 16

  • Number of programmable relay outputs: 2, 4, 6, 8, 12, 16

  • Number of conventional wired zone inputs (hybrid): 4, 8, 16, 32

Communication to Central Station

  • Ethernet 10/100/1000 Base-T

  • Wi-Fi 2.4GHz and 5GHz (WPA2/WPA3)

  • 4G LTE Cat 1, Cat 4, or Cat M1 (global band support)

  • Dual communication paths (Ethernet + cellular for redundancy)

  • Protocols: Contact ID (Ademco), SIA DC-09, REST API, or custom

Power and Battery

  • Primary power: 110-240V AC 50/60Hz (universal input)

  • Battery backup: 12V 7Ah, 12V 12Ah, 12V 26Ah, or 12V 40Ah

  • Battery charger: built-in, automatic, temperature-compensated

  • External 24V DC output: 2A, 3A, 5A, or 10A for powering external devices

Software and Platform

  • White-label firmware with your branding on startup screens

  • White-label web server interface with your logo and colors

  • White-label mobile APP for remote access (iOS and Android)

  • API for integration with building management systems (BACnet, Modbus)

  • Custom reporting templates for compliance and inspection

Packaging and Labeling

  • Custom packaging with your branding

  • Custom labels with serial number, UL/CE/FCC marks

  • Multi-language user manuals and installation guides

  • Custom programming software with your branding

Certification Support

  • UL864 (United States) for fire alarm control panels

  • EN54-2 (control and indicating equipment) and EN54-4 (power supplies) for Europe

  • CE (LVD, EMC, RED) for Europe

  • FCC (United States) for radio

  • UKCA for United Kingdom

  • RCM for Australia

Low MOQ for Trial Orders – as few as 10 panels for selected models
Fast Sampling – 20 to 30 working days for custom samples including custom branding and colors
Full Technical Documentation – for product registration, market approval, and insurance compliance
Dedicated R&D Support – for custom radio configurations, enclosure designs, and software features

Visit Our Factory – We Reimburse Your Airfare and Provide Free Stay

We believe the best partnership is built on trust – and trust is built face to face.

For serious global partners including distributors, importers, sourcing agents, system integrators, and volume buyers, Wanlin offers:

  • Round-trip airfare reimbursement – economy class tickets, upon confirmed order or signed partnership agreement

  • Free accommodation – quality hotel stay during factory inspection days for up to 3 nights

  • Free local meals and transportation – airport pickup, all meals, and local travel during your visit

During your visit, you will:

  • Tour our production lines and witness LoRa fire alarm control panel assembly and testing

  • See our LoRa gateway testing laboratory with spectrum analyzers and range test equipment

  • Test panel operation with 50-100 wireless detectors in live demonstration

  • Review web interface, mobile APP, and central station reporting

  • Examine battery backup and power supply testing

  • Meet our firmware engineers and software developers

  • Discuss custom enclosure designs, radio configurations, and software features

  • Review export documentation, supply chain processes, and quality assurance protocols

  • Visit our warehouse and see finished goods ready for shipment

  • Discuss long-term partnership agreements, exclusive territory arrangements, and OEM customization options

This offer applies to genuine buyers, distributors, and long-term cooperation seekers. Contact us for eligibility details and complete terms.

Our Global Partnership Model – Win-Win, Quality First

Wanlin is committed to cooperative success. We do not chase short-term profits. We build long-term relationships based on quality, service, and mutual growth.

Partner TypeWhat We Offer
Fire Safety DistributorBulk pricing with tiered volume discounts, container shipping options, exclusive territory discussion, stock holding support, marketing materials highlighting LoRa wireless advantages, demo panels for showroom
Fire Alarm System IntegratorLoRa panels with open API, custom integration support, technical documentation, long-term supply agreement, on-site training available
Industrial Facility SupplierComplete LoRa fire alarm systems for factories, warehouses, solar farms, ports, mines; site-specific engineering; extended warranties
Campus Security IntegratorLoRa panels for university campuses, corporate campuses, hospital campuses; multi-building single-panel solution
OEM CustomerWhite-label LoRa panels with your brand, custom firmware, custom enclosure, long-term supply agreement, NDA and exclusivity
Government Tender SupplierVolume pricing for large-scale public safety projects, complete UL/CE certification packages, drop-shipping to multiple locations
Smart Building IntegratorLoRaWAN standard panels for smart building integration, BACnet/Modbus interfaces, API access

Our Values

  • Quality Guarantee – 100 percent pre-shipment inspection, LoRa radio testing, device pairing validation, battery charger testing, environmental testing, 1-year warranty with replacement guarantee

  • Responsive Service – English-speaking export team, reply within 24 hours (typically within 12 hours), technical support for panel configuration and central station integration

  • Fair Pricing – No hidden fees, transparent cost breakdown, volume discounts automatically applied

  • Shared Growth – Marketing materials, product catalogs, technical white papers on LoRa fire alarm technology, installation guides, software demo, documentation provided free

  • Long-term Commitment – Regular communication, quarterly reviews, continuous product and software improvement

Complete Export Solution – From Our Factory to Your Warehouse

When you partner with Wanlin, you get a turnkey export service designed for hassle-free international trade.

Customization and Branding

  • Custom enclosure color and logo – your brand, your design

  • Custom firmware with your branding on display

  • Custom web interface and mobile APP with your logo

  • Custom user manuals with installation guides – we translate and design

  • Sample approval before mass production

Quality Control

  • In-line quality control during production at each assembly stage

  • LoRa gateway radio testing (TX power, RX sensitivity) on every panel

  • Device pairing and communication testing with 50-100 test detectors

  • Notification appliance circuit (NAC) output testing

  • Relay output testing (voltage, current, timing)

  • Battery charger verification (voltage, current, temperature compensation)

  • Ethernet, Wi-Fi, and 4G cellular communication testing

  • Event logging verification

  • Environmental chamber testing on batch samples

  • 100 percent final functional testing before packaging

  • Third-party inspection supported including SGS, BV, TUV, Intertek, UL

Shipping and Logistics

  • Full shipping documents: Commercial Invoice, Packing List, Bill of Lading, Certificate of Origin, Form E, CE/UL/FCC declarations, radio certification documents

  • Flexible shipping: sea freight (FCL or LCL), air freight, express (DHL, FedEx, UPS)

  • DDP available for select countries

After-Sales Support

  • Technical hotline for panel configuration, device pairing, and central station integration

  • Firmware updates provided via USB or network

  • Spare parts supply guaranteed for 5 years

  • Warranty returns processing

  • Online training sessions for your sales and technical teams

We have successfully exported to North America, Europe, Southeast Asia, the Middle East, South America, Africa, and Australia.

Applications for LoRa Fire Alarm Control Panels

Wanlin's LoRa fire alarm control panels are ideal for large-scale, campus, industrial, and retrofit applications.

  • Industrial Facilities – factories, warehouses, power plants, refineries, chemical plants

  • University Campuses – multiple buildings, central monitoring, no inter-building cabling

  • Corporate Campuses – office buildings, parking structures, amenity buildings

  • Hospital Campuses – medical buildings, outpatient facilities, research centers

  • Solar Farms and Wind Farms – remote site monitoring, wide area coverage

  • Ports and Shipping Terminals – outdoor areas, multiple buildings, pier structures

  • Airports – terminals, hangars, parking garages, cargo facilities

  • Retail Centers – shopping malls, big box stores, strip malls

  • Hotels and Resorts – multiple buildings, guest rooms, convention centers

  • Senior Living Communities – multiple buildings, common areas, healthcare wings

  • K-12 School Districts – multiple schools monitored from central location

  • Historic Buildings – no destructive wiring allowed

  • Construction Sites – temporary protection, portable panels

  • Government Facilities – secure installations, multiple buildings

Comparison Guide – LoRa Panel versus Traditional Wired Panel

FeatureWired Fire Alarm PanelLoRa Fire Alarm Panel by Wanlin
Wiring between panel and detectorsRequired (2-4 conductors per device)No wiring required
Installation costHigh ($200-500 per device)Low ($50-100 per device)
Installation timeWeeksDays
Retrofit capabilityDifficult (requires destructive work)Easy (surface mount detectors)
Maximum device rangeDetermined by wiring2-10km wireless
Building-to-buildingRequires trenching/cablingWireless (2-10km)
Expansion costHigh (cable pulling, patching)Low (add detectors, pair)
Detector battery lifeN/A (wired power)5-10 years
Remote device status monitoringNo (only alarm/trouble)Yes (battery, signal, tamper, health)
Best applicationNew construction, high-riseCampuses, retrofits, industrial, large facilities

Join Us as a Global Partner Today

You do not need to be the biggest company. You just need a reliable, honest, and capable manufacturer who treats you as a true partner.

Email: wanlinfirecontrol@163.com
Export Hotline (WhatsApp, WeChat, Phone): +86 13261677119
Official Website: www.wanlinfire.com